923 research outputs found

    Cantilever-based Resonant Microsensors with Integrated Temperature Modulation for Transient Chemical Analysis

    Get PDF
    This work introduces a resonant cantilever platform with integrated temperature modulation for real-time chemical sensing. Embedded heaters allow for rapid thermal cycling of individual sensors, thereby enabling real-time transient signal analysis without the need for a microfluidic setup to switch between analyte and reference gases. Compared to traditional mass-sensitive microsensors operating in steady state, the on-chip generation of signal transients provides additional information for analyte discrimination

    Unconventional Uses of Microcantilevers as Chemical Sensors in Gas and Liquid Media

    Get PDF
    The use of microcantilevers as (bio)chemical sensors usually involves the application of a chemically sensitive layer. The coated device operates either in a static bending regime or in a dynamic flexural mode. While some of these coated devices may be operated successfully in both the static and the dynamic modes, others may suffer from certain shortcomings depending on the type of coating, the medium of operation and the sensing application. Such shortcomings include lack of selectivity and reversibility of the sensitive coating and a reduced quality factor due to the surrounding medium. In particular, the performance of microcantilevers excited in their standard out-of-plane dynamic mode drastically decreases in viscous liquid media. Moreover, the responses of coated cantilevers operating in the static bending mode are often difficult to interpret. To resolve these performance issues, the following emerging unconventional uses of microcantilevers are reviewed in this paper: (1) dynamic-mode operation without using a sensitive coating, (2) the use of in-plane vibration modes (both flexural and longitudinal) in liquid media, and (3) incorporation of viscoelastic effects in the coatings in the static mode of operation. The advantages and drawbacks of these atypical uses of microcantilevers for chemical sensing in gas and liquid environments are discussed

    Unconventional Uses of Cantilevers for Chemical Sensing in Gas and Liquid Environments

    Get PDF
    Microcantilevers used as (bio)chemical sensors are usually coated with a chemically sensitive layer. The coated devices operate either in a static bending regime or in a dynamic flexural mode. While the coated devices operate generally well in both the static and dynamic mode, they do suffer from certain shortcomings depending on the medium of operation and the application, including lack of selectivity and of reversibility of the sensitive coating and a reduced quality factor due to the surrounding medium. In particular, the performance of microcantilevers excited in their standard out-of-plane dynamic mode drastically decreases in viscous liquid media. Moreover, the responses of coated cantilevers operating in the static bending mode are often difficult to interpret. To resolve those performance issues, unconventional uses of microcantilever are reviewed in this paper, which consist of the use of the dynamic mode without sensitive coating, the use of in-plane (flexural and longitudinal) vibration modes in liquid media, and fully accounting for the viscoelastic effects of the coatings in the static mode of operation. The advantages and drawbacks of these unconventional uses of microcantilevers for chemical sensing in gas and liquid environments are discussed

    Analysis of the Detection of Organophosphate Pesticides in Aqueous Solutions Using Hydrogen-Bond Acidic Coating on SH-SAW Devices

    Get PDF
    The work presented in this paper focuses on the synthesis and characterization of a hybrid organic/inorganic chemically sensitive layer for rapid detection and analysis of OPs in aqueous solutions using SH-SAW devices. Coated SH-SAW devices on 36° YX-LiTaO and 42.75° YX-Quartz (ST-90° X Quartz), are used to determine the optimum operating conditions for achieving rapid sensor responses with high sensitivity. Three analytes (parathion-methyl, parathion, and paraoxon), having similar molecular mass and volume, are used to evaluate the performance of the hybrid organic/inorganic coating in terms of sensor properties of interest including sensitivity, selectivity, reproducibility. It is shown that the coating has a high degree of partial selectivity and sensitivity towards the analytes. With the present non-optimized chemical sensor, a limit of detection of 60 (ppb), 20 (ppb) and 100 (ppb) is estimated for parathion-methyl, parathion, and paraoxon, respectively, when using a 0.5 -thick BPA-HMTS sensing layer. Concentrations as low as 500 (ppb) parathion have been measured. This concentration is significantly much lower than the typical concentrations found on agricultural produce (≥10 ppm)

    Cantilever-based Resonant Gas Sensors with Integrated Recesses for Localized Sensing Layer Deposition

    Get PDF
    This work presents mass-sensitive hammerhead resonators with integrated recesses as a gas-phase chemical microsensor platform. Recesses are etched into the head region of the resonator to locally deposit chemically sensitive polymers by ink-jet printing. This permits the sensing films to be confined to areas that (a) are most effective in detecting mass loading and (b) are not strained during the in-plane vibrations of the resonator. As a result of the second point, even 5-μm thick polymer coatings on resonators with a 9-12 μm silicon thickness barely affect the Q-factor in air. This translates into higher frequency stability and ultimately higher sensor resolution compared to uniformly coated devices

    Effect of Hydrodynamic Force on Microcantilever Vibrations: Applications to Liquid-Phase Chemical Sensing

    Get PDF
    At the microscale, cantilever vibrations depend not only on the microstructure’s properties and geometry but also on the properties of the surrounding medium. In fact, when a microcantilever vibrates in a fluid, the fluid offers resistance to the motion of the beam. The study of the influence of the hydrodynamic force on the microcantilever’s vibrational spectrum can be used to either (1) optimize the use of microcantilevers for chemical detection in liquid media or (2) extract the mechanical properties of the fluid. The classical method for application (1) in gas is to operate the microcantilever in the dynamic transverse bending mode for chemical detection. However, the performance of microcantilevers excited in this standard out-of-plane dynamic mode drastically decreases in viscous liquid media. When immersed in liquids, in order to limit the decrease of both the resonant frequency and the quality factor, and improve sensitivity in sensing applications, alternative vibration modes that primarily shear the fluid (rather than involving motion normal to the fluid/beam interface) have been studied and tested: these include in-plane vibration modes (lateral bending mode and elongation mode). For application (2), the classical method to measure the rheological properties of fluids is to use a rheometer. However, such systems require sampling (no in-situ measurements) and a relatively large sample volume (a few milliliters). Moreover, the frequency range is limited to low frequencies (less than 200Hz). To overcome the limitations of this classical method, an alternative method based on the use of silicon microcantilevers is presented. The method, which is based on the use of analytical equations for the hydrodynamic force, permits the measurement of the complex shear modulus of viscoelastic fluids over a wide frequency range

    Influence of Fluid-Structure Interaction on Microcantilever Vibrations: Applications to Rheological Fluid Measurement and Chemical Detection

    Get PDF
    At the microscale, cantilever vibrations depend not only on the microstructure’s properties and geometry but also on the properties of the surrounding medium. In fact, when a microcantilever vibrates in a fluid, the fluid offers resistance to the motion of the beam. The study of the influence of the hydrodynamic force on the microcantilever’s vibrational spectrum can be used to either (1) optimize the use of microcantilevers for chemical detection in liquid media or (2) extract the mechanical properties of the fluid. The classical method for application (1) in gas is to operate the microcantilever in the dynamic transverse bending mode for chemical detection. However, the performance of microcantilevers excited in this standard out-of-plane dynamic mode drastically decreases in viscous liquid media. When immersed in liquids, in order to limit the decrease of both the resonant frequency and the quality factor, alternative vibration modes that primarily shear the fluid (rather than involving motion normal to the fluid/beam interface) have been studied and tested: these include inplane vibration modes (lateral bending mode and elongation mode). For application (2), the classical method to measure the rheological properties of fluids is to use a rheometer. To overcome the limitations of this classical method, an alternative method based on the use of silicon microcantilevers is presented. The method, which is based on the use of analytical equations for the hydrodynamic force, permits the measurement of the complex shear modulus of viscoelastic fluids over a wide frequency range

    Entanglement and squeezing in a two-mode system: theory and experiment

    Full text link
    We report on the generation of non separable beams produced via the interaction of a linearly polarized beam with a cloud of cold cesium atoms placed in an optical cavity. We convert the squeezing of the two linear polarization modes into quadrature entanglement and show how to find out the best entanglement generated in a two-mode system using the inseparability criterion for continuous variable [Duan et al., Phys. Rev. Lett. 84, 2722 (2000)]. We verify this method experimentally with a direct measurement of the inseparability using two homodyne detections. We then map this entanglement into a polarization basis and achieve polarization entanglement.Comment: submitted to J. Opt. B for a Special Issue on Foundations of Quantum Optic

    Étude physico-chimique des cendres de quelques végétaux du Benin utilisées dans la fabrication du savon «ACOTO»

    Get PDF
    Elaeis guineensis, Grossypium arborium, Anogeissus leiocarpus et Acacia sieberiana sont des matériaux végétaux dont incinérées, certaines parties sont utilisées dans la préparation du savon artisanal «ACOTO» au Bénin. Notre travail a pour objectif de déterminer la durée optimale de conservation du substrat de cendres de ces matériaux végétaux utilisés pour l’obtention d’une meilleure qualité de savon puis de faire une caractérisation physico-chimique des cendres de ces matériaux végétaux. Les analyses physico-chimiques ont montré que tous les substrats de cendres issues de ces matériaux végétaux sont alcalins (7,35< pH <10,02) et contiennent pour la plupart une concentration élevée en K+, ce qui confirme leur alcalinité. Les analyses révèlent également que la durée optimale de conservation de tous les substrats sauf ceux de la cendre des tiges de Acacia sieberiana et de la cendre du tronc de Elaeis guineensis est environ d’une (1) heure avant la préparation du savon.Mots clés: Savon «ACOTO», Elaeis guineensis, Grossypium arborium, Anogeissus leiocarpus, Acacia sieberiana, Béni

    Pentaerythritol based push–pull tetramers for organic photovoltaics

    Get PDF
    The synthesis and characterization of two tetramers based on the functionalization of a central pentaerythritol σ-linker with push–pull chromophores is reported herein. Prepared in only few steps, these original molecules exhibit interesting optical and electrochemical properties. Moreover, once evaluated as donor materials, promising power conversion efficiencies of 4.5% were reached when blended with the [6,6]-phenyl-C71-butyric acid methyl ester (PC71BM) in bulk heterojunction solar cells
    • …
    corecore